RWSN Library

Author
Government of Zimbabwe
Year of Publishing
2013
Publisher
The Zimbabwe Government
Institution
The Zimbabwe Government
INSPECTION AND EXAMINATION CHARTS FOR PUMP HEAD AND “DOWN THE HOLE” COMPONENTS OF B TYPE BUSH PUMP Extract from National Standards Specifications - SAZS 881:2013 (Appendix B and C)
Description:
The Pump head is inspected by mounting and bolting the pump head on to a pump stand which is set (with a spirit level) in a vertical position. The “down the hole” components are an essential part of any Bush Pump installation. In the standard design, they consist of both steel (ferrous) and brass (non ferrous ) components.
Bibliographical Information:
Government of Zimbabwe (2013) INSPECTION AND EXAMINATION CHARTS FOR PUMP HEAD AND “DOWN THE HOLE” COMPONENTS OF B TYPE BUSH PUMP. Extract from National Standards Specifications - SAZS 881:2013 (Appendix B and C) , The Zimbabwe Government , The Zimbabwe Government
DOWNLOADS (28)
B Type Bush Pump - INSPECTION CHART for “DOWN THE HOLE” COMPONENTS
EXAMINATION CHART FOR INSPECTION FOR “B” TYPE BUSH PUMP HEAD