		INSPECTION AND EXAMINATION CHARTS FOR PUMP HEAD AND  “DOWN THE HOLE” COMPONENTS OF B TYPE BUSH PUMP		
		Extract from National Standards Specifications - SAZS 881:2013 (Appendix B and C)		
		
		
			
	Description:
The Pump head is inspected by mounting and bolting the pump head on to a pump stand which is set (with a spirit level) in a vertical position. The “down the hole” components are an essential part of any Bush Pump installation. In the standard design, they consist of both steel (ferrous) and brass (non ferrous ) components.
Bibliographical Information:
Government of Zimbabwe (2013) INSPECTION AND EXAMINATION CHARTS FOR PUMP HEAD AND “DOWN THE HOLE” COMPONENTS OF B TYPE BUSH PUMP. Extract from National Standards Specifications - SAZS 881:2013 (Appendix B and C) , The Zimbabwe Government , The Zimbabwe Government
DOWNLOADS (32)
B Type Bush Pump - INSPECTION CHART for “DOWN THE HOLE” COMPONENTS
EXAMINATION CHART FOR INSPECTION FOR “B” TYPE BUSH PUMP HEAD