The Zimbabwe Government
INSPECTION AND EXAMINATION CHARTS FOR PUMP HEAD AND “DOWN THE HOLE” COMPONENTS OF B TYPE BUSH PUMP Extract from National Standards Specifications - SAZS 881:2013 (Appendix B and C)
Description:
The Pump head is inspected by mounting and bolting the pump head on to a pump stand which is set (with a spirit level) in a vertical position. The “down the hole” components are an essential part of any Bush Pump installation. In the standard design, they consist of both steel (ferrous) and brass (non ferrous ) components.