RWSN Ressources
Author
Year of Publishing
2002
Publisher
Community Water and Sewerage Agency, Ghana
Institution
Community Water and Sewerage Agency, Ghana
Ghana Modified India Mark II
Description:
The Ghana Modified India Mark II handpump was developed as a response to the problem of rapidly corroding handpumps installed in aggressive groundwaters.
The modifications include the use of stainless steel riser pipe and stainless steel pump rods, as well as the use of a stainless steel flange at the water tank, installed with an insulating gasket to prevent galvanic corrosion. This type of corrosion occurs when two dissimilar metals are in contact in solution.
Bibliographical Information:
(2002) Ghana Modified India Mark II. , Community Water and Sewerage Agency, Ghana , Community Water and Sewerage Agency, Ghana
More Information
DOWNLOADS (94)
Ghana Modified India Mark II Drawings
SPECIFICATION MODIFIED INDIA MK II GHANA VERSION 2009